Erro do indicador de velocidade

Turco: Hava Hızı Göstergesi Hatası

PPLATPLIR Instrumentos de voo
IN SHORT

The deviation of the airspeed indicator from the true airspeed, caused by pitot-static system faults, calibration errors or instrument errors.

O que é Erro do Indicador de Velocidade?

The airspeed indicator (ASI) shows airspeed by measuring the difference between dynamic and static pressure through the pitot-static system. Any malfunction, blockage, leak or calibration error in this system causes the indicated speed to deviate from the true airspeed (TAS). Typical causes are icing of the pitot tube, water in the pitot tube, blockage of the static port, or mechanical failure of the instrument.

Airspeed indicator error is critical for flight safety. Relying on incorrect speed information, the pilot may exceed the stall speed, miscalculate take-off and landing performance, or violate speed limits. Failure of the pitot heater or blockage of the static port are common causes, especially in icing conditions.

Pitot-static system checks (pitot check, static port check) and instrument calibration must be carried out regularly. Pre-flight checks confirm that the ASI reads zero on the ground and gives consistent readings in normal weather conditions. If an error is suspected, alternative speed sources (GPS speed, radar speed) may be used.

Exemplo

If the pitot tube ices over, the ASI may suddenly indicate a low speed. If the static port is blocked, the ASI indicates a lower speed at high altitude. For example, the ASI may show 95 knots while the TAS is 120 knots.

Frequentemente confundido com

Fault TypeIndicação do ASICausa
Obstrução do pitotIndicates lowPerda de pressão dinâmica
Obstrução da tomada estáticaIndicates highPerda de pressão estática
Formação de gelo no pitotQueda repentina / flutuaçãoFalha do aquecedor do pitot
Falha do instrumentoFixed / does not resetDano mecânico
TEST YOURSELF

What does the airspeed indicator show if the static port is blocked?

Frequently asked questions about Airspeed Indicator Error

What does the airspeed indicator show if the pitot tube ices over?

In the case of airspeed indicator error, if the pitot tube ices over the ASI may suddenly indicate a low speed. The pilot may then exceed the stall speed by relying on incorrect speed information.

How is airspeed indicator error checked?

Before flight, the ASI is checked to read zero on the ground and to give consistent readings in normal weather conditions. Pitot-static system checks and instrument calibration must be carried out regularly.

Which speed sources can a pilot use if an ASI error is suspected?

If airspeed indicator error is suspected, alternative speed sources such as GPS speed or radar speed may be used. Incorrect speed information may lead to violation of speed limits.