Holding Entry Procedures: Entering the Holding Pattern: the full explanation
Published: · Updated: · By: Son Yaklaşma editorial team
Entry sector summary (standard right-hand holding)
| Procédure d'entrée | Largeur du secteur | Plage de l'angle relatif | Comment le voler ? |
|---|---|---|---|
| Directe | ≈ 180° | 0°–110° et 290°–360° | Pass over the fix, then turn directly to the holding side and enter the outbound leg. |
| Parallèle | 110° | 180°–290° | Pass over the fix, fly parallel to the inbound course in the reverse (outbound) direction for approximately 1 minute, then turn towards the holding side and intercept the inbound track. |
| En larme | 70° | 110°–180° | Pass over the fix, fly for approximately 1 minute on a heading offset 30° towards the holding side, then turn back onto the inbound track. |
In left-hand (non-standard) holding the sectors are mirror images. Unless ATC specifies otherwise, holding is right-hand.
Exemple travaillé : quelle entrée ?
Holding: inbound course 270°, right-hand (holding side north), outbound course 090°. Relative angle = aircraft's arrival heading to the fix − inbound course (add 360 if negative).
| Arrival heading | Relative angle | Entrée | Après le repère |
|---|---|---|---|
| 300° | 300 − 270 = 30° | Directe | Turn right and fly directly onto the outbound 090°. |
| 045° | 045 − 270 + 360 = 135° | En larme | Offset 30° towards the holding side and fly 060° for 1 minute, turn right and intercept the inbound 270°. |
| 180° | 180 − 270 + 360 = 270° | Parallèle | Fly outbound 090° for 1 minute on the non-holding side (south), turn left and return to the fix. |
For left-hand holding, to use the same table take 360 − relative angle instead of the relative angle.
Dimensions du circuit d'attente
- Turn rate: Standard rate turn (360° per minute, i.e. 3°/s) or the bank angle of 25°, whichever requires the lower bank angle, is used.
- Durée de l'éloignement : 1 minute à 14,000 ft et en dessous, 1.5 minutes au-dessus de 14,000 ft. Le temps est mesuré après le passage du repère à l'entrée et sur la branche d'éloignement.
- Route d'approche (IC) et route d'éloignement (OC) : OC = IC ± 180°.
Erreurs courantes
- Reading the sector the wrong way. For right-hand and left-hand holding the parallel and teardrop sectors swap places; always check the holding side first.
- Confusing arrival heading with inbound course. Relative angle is the difference between the route the aircraft flies as it approaches the fix and the inbound course, not the aircraft's nose direction.
- Starting the timing late on entry. On parallel and teardrop entries the 1-minute timing starts after passing over the fix.
In the exam mode of the simulation above, a random heading and inbound course are given; choose the entry procedure yourself, and the correct track line appears.
What is the holding pattern?
Holding pattern, is a racetrack-shaped route flown by an aircraft around a holding fix: an inbound leg, a 180° turn at the fix, an outbound leg and a second 180° turn. Entering the holding pattern is the first way of joining this route and is done with one of the three entry procedures above. Once the pattern is established, see the lesson how to fly a holding pattern for timing, abeam point and wind correction, and visit the Holding Trainer for quick practice with ATC clearance texts.
Comment détermine-t-on la procédure d'entrée en attente ?
- Déterminez la route d'entrée. Obtenez la route d'entrée (IC) auprès du contrôle ou sur la carte de procédure. C'est votre route d'approche vers le repère d'attente.
- Calculer la direction d'arrivée. Notez le cap actuel de l'aéronef. Calculez la différence entre la direction d'arrivée et la route d'entrée.
- Apprenez le sens du circuit d'attente. Le contrôle précise si un circuit à droite (standard) ou à gauche (non standard) est requis. Le circuit standard est à droite.
- Déterminer le secteur. Attente à virage à droite : relèvement relatif 0°–110° et 290°–360° signifie direct, 180°–290° signifie parallèle, 110°–180° signifie entrée en goutte d'eau.
- Appliquer l'entrée. À l'approche du repère d'attente, appliquez la procédure d'entrée choisie (directe, parallèle ou en goutte d'eau) et rejoignez le circuit d'attente.
Questions fréquemment posées
What is the holding pattern?
The holding pattern is a racetrack-shaped route flown by an aircraft around a holding fix on ATC instruction: an inbound leg towards the fix, a 180° turn, an outbound leg away from the fix and another 180° turn. Known in English as the holding pattern, or simply holding. It is used to keep an aircraft within a specific area and altitude during situations such as heavy traffic, bad weather or runway closure.
How to enter the holding pattern?
Entry into the holding pattern is made using one of three procedures selected by the relative angle between the aircraft's arrival heading to the holding fix and the inbound course: direct entry, parallel entry or teardrop entry. Relative angle = arrival heading − inbound course; for right-hand holding, 110°–180° is teardrop, 180°–290° is parallel, and the remainder is direct entry. In all three entries the aircraft first passes over the fix.
Quelles sont les procédures d'entrée en attente ?
Selon les procédures OACI, il existe trois procédures d'entrée en attente : entrée directe, entrée parallèle et entrée en goutte d'eau. La procédure à appliquer est déterminée par l'angle entre la direction d'arrivée de l'aéronef au repère d'attente et la route d'entrée.
Quand l'entrée directe est-elle appliquée ?
Dans une attente à virages à droite, si la route d'arrivée de l'aéronef par rapport à la route d'entrée se situe dans le secteur 0°–110° et 290°–360° (environ 180° au total), une entrée directe est utilisée. L'aéronef franchit le repère et vire directement vers le côté de l'attente pour entrer dans la branche de sortie.
Quand l'entrée parallèle est-elle appliquée ?
Dans un circuit à droite, si la route d'arrivée de l'aéronef par rapport à la route d'approche se situe dans le secteur 180°–290° (large de 110°, du côté où se trouve le circuit), une entrée parallèle est utilisée. L'aéronef franchit le repère, vole dans le sens inverse de la route d'approche (direction éloignement) pendant environ 1 minute, puis vire vers le côté du circuit et intercepte la route d'approche.
Quand applique-t-on l'entrée en goutte d'eau ?
Dans un circuit à droite, si la route d'arrivée de l'aéronef par rapport à la route d'entrée se situe dans le secteur 110°–180° (large de 70°, du côté opposé au circuit), on utilise une entrée en goutte d'eau. L'aéronef franchit le repère, vole pendant environ 1 minute sur un cap décalé de 30° vers le côté du circuit, puis vire pour intercepter la route d'entrée.
Comment les secteurs changent-ils dans une attente à virages à gauche ?
Dans une attente à virages à gauche (non standard), les secteurs sont l'image miroir de ceux d'une attente à virages à droite. Le secteur d'entrée parallèle passe du côté droit et le secteur en goutte d'eau passe du côté gauche.
Qu'est-ce que la route d'entrée et la route de sortie ?
La route d'approche (IC) est la route magnétique que suit l'aéronef en approchant du repère d'attente. La route d'éloignement (OC) est le inverse exact de la route d'approche (IC + 180°) ; l'aéronef suit cette route sur la branche d'éloignement. Dans le circuit d'attente, l'aéronef alterne en permanence entre la branche d'approche et la branche d'éloignement.
Combien de minutes dure la branche sortante du circuit d'attente ?
Selon le PANS-OPS de l'OACI, la branche sortante dure 1 minute à 14,000 ft et en dessous, et 1.5 minutes au-dessus de 14,000 ft. Le temps est mesuré après le passage du repère à l'entrée et sur la branche sortante.
À quelle vitesse les virages sont-ils effectués dans le circuit d'attente ?
Les virages sont effectués au taux standard (360° par minute, soit 3°/s) ou avec une inclinaison de 25° ; on utilise celui qui nécessite la plus faible inclinaison.
Sources
- OACI Doc 8168 (PANS-OPS), Volume I : procédures d'attente et méthodes d'entrée
- FAA, Aeronautical Information Manual (AIM) : Attente